JM Modern HikaShop - шаблон joomla Видео
(06-1) 463-5077
E-mail
Molecular Devices

ImageXpress Pico Automated Cell Imaging System

ImageXpress PicoRight-lo
ImageXpress Pico-209-lo
Intelligent cell imaging and analysis integrated in a single, affordable system
More than a digital microscope, the ImageXpress® Pico system combines imaging and powerful analysis for individual labs that need easy automated imaging solutions. After a simple step-by-step setup, images are automatically acquired and analyzed while users can work on other tasks. The CellReporterXpress software offers advanced features that simplify user experience while generating data-rich results. Outputs can be viewed in many formats including heat maps, scatter plots, and videos.

ÁRAJÁNLATOT, INFORMÁCIÓT KÉREK!

 

How It Works

Preconfigured cell imaging protocol in CellReporterXpress software

Analysis screen of the CellReporterXpress software

Generate scatter plots from your cell images using the CellReporterXpress

Acquisition

Place the microplate or slide into the system, and after a few clicks in the software, the system will run automatically and allow users to have walkaway time.

No special requirements such as a dark room or air table are needed.

 

Analysis

View results, which are automatically extracted from images, in various formats including an image montage, bar graphs, tables, scatter plots, and even videos. 

The system can run and analyze a variety of assays ranging from simple cell counting to sophisticated neurite tracing.

 

Answers

Export and share data and images easily for presentations and publications with built-in sharing and remote access capabilities. The system can be accessed and operated online via Chrome or Safari.

 

Benefits

SAVE TIME ON SETUP
Save time on setup with ImageXpress Pico system

With the approachable, icon-driven CellReporterXpress software, everyone can use the ImageXpress Pico system with minimal training to capture and analyze your first image. 

DO MORE THAN CELL COUNTING
Do more than cell counting with ImageXpress Pico system

Expand your assays beyond cell counting with preconfigured templates for many commonly used cell imaging and analysis protocols including apoptosis and detection of mitochondria.

AUTOMATE YOUR IMAGING AFFORDABLY
Automate your cell imaging affordably

Alleviate the hassle of going to the core lab to run your samples. The ImageXpress Pico system’s lab-friendly price affords the convenience of automated imaging and analysis on your lab bench.

Features
MULTIPLE IMAGING MODES
Brightfield image overlay with fluorescence mask

The ImageXpress Pico system provides user- and software-selectable objectives ranging from 4X to 63X, fluorescence imaging, live cell imaging, and brightfield imaging modes. 

PREDEFINED CELL IMAGING PROTOCOLS
The ImageXpress Pico's preconfigured cell imaging protocols range from simple cell count to sophisticated neurite tracing analysis

The system offers preconfigured cell imaging protocols ranging from simple cell count to sophisticated neurite tracing analysis, removing the guesswork from optimizing parameters. 

PLATE-TO-INDIVIDUAL CELL VIEW
Visualize cell images from plate overviews to individual cells

Data can be visualized at multiple levels from plate overviews to individual cells. Images are clickable to locate cells that match specific criteria.

INTEGRATED DATA VISUALIZATION TOOLS
The ImageXpress Pico Automated Cell Imaging System can transform images into data on the fly.

More than a digital microscope, the imager’s analysis software transforms images into data on the fly. Heat maps, scatter plots, videos, and more can be generated from automatically extracted cell data with a few clicks.

 

ADVANCED SLIDE-IMAGING WORKFLOW

The whole slide can be quickly scanned to generate an overview image that helps locate regions of interest.  The user can then select multiple regions of interest to acquire images at a higher resolution, reducing time and data storage space.

The advanced slide-imaging workflow in ImageXpress Pico system saves time and data storage space


REMOTE ACCESS CAPABILITY
The ImageXpress Pico system can be accessed anywhere.

The Chrome- or Safari-based software enables access and convenient operation of the system from anywhere, even when away from the lab. 

ENVIRONMENTAL CONTROL AND INJECTORS
The ImageXpress Pico system offers environmental control.

Temperature control up to 40◦C is standard on every ImageXpress Pico system, making live cell imaging a possibility. Additional configurable options include humidity, gas, and injectors.

 

Műszaki specifikációk

 

Specifications
Modes of operation White light/brightfield, colorimetric, fluorescence
Objectives 6 position automated turret with user-exchangeable
objectives. Optics by Leica
Microsystems: FLUOTAR 4x/NA 0.13, 10x/NA
0.32, 20x/NA 0.40, 40x/NA 0.60, 63x/NA 0.70
Channels Cy5, TRITC, FITC, DAPI, white light, and RGB
Autofocus method Hardware or Image with hardware assist
Supported labware 6- to 384-well plates and slides
Supported operating systems Windows 10 (main computer), Windows 10 and macOS (clients)
Environmental control
  • Incubation up to 40°C (standard)
  • CO2: 0.1%–20% (optional)
  • O2: 1–19% (optional
  • Humidity control for minimizing evaporation (optional)
Injector option
  • 2 channels
  • Dispensing volume is at 1 μL increments from 1 μL to maximum allowable volume of the well
Dimensions (cm) 45.3 (H) x 55.1 (W) x 43.5 (D)
Weight (kg) 38 kg including options
 
 
Applikációk

 

Over 25 preconfigured cell imaging protocols are available. Some of the commonly used ones are listed below.

Angiogenesis

Angiogenesis

Apoptosis

Apoptosis

Autophagy

Autophagy

Cell Count

Cell Count

Cell Count - Transmitted Light

Cell Count - Transmitted Light

Cell Differentiation

Cell Differentiation

Cell Scoring

Cell Scoring

Cell Scoring - Transmitted Light

Cell Scoring - Transmitted Light

Endocytosis

Endocytosis

Internalization

Internalization

Live Cells

Live Cells

Lysosomes

Lysosomes

Mitochondria

Mitochondria

Mitotic Index

Mitotic Index

Neurite Tracing

Neurite Tracing

Phagocytosis

Phagocytosis

Pits and Vesicles or Endosomes

Pits and Vesicles or Endosomes

Protein Expression Index

Protein Expression Index

Viral Infectivity

Viral Infectivity

 

 

 

Tartozékok, kiszerelések

 

The ImageXpress Pico system offers environmental control.

Temperature control up to 40◦C is standard on every ImageXpress Pico system, making live cell imaging a possibility. Additional configurable options include humidity, gas, and injectors.

 

Videók, ismertetők
Újdonság
Újdonság

blue down arrowForgalmazott termékeink gyártói