JM Modern HikaShop - шаблон joomla Видео
In
(06-1) 619-8321
Custom BioGenic Systems

Isothermal Liquid Nitrogen Freezers

V1500 Cut Away W LN2 Text
Isothermal W Gray Gradient
Az igazi száraz tárolás -192C-on.
Ezzel az unikális termékkel minimálisra csökkenthető a minták keresztfertőződésének és a személyi baleseti kockázatok veszélye.


ÁRAJÁNLATOT, INFORMÁCIÓT KÉREK!

V1500-AB, V3000-AB, V5000-AB, V5000EH-AB

Liquid Nitrogen Isothermal  non-emersion storage

  • Dry storage greatly reduces the risk of cross contamination.
  • Added user safety by eliminating liquid nitrogen contact.
  • Utilize the entire storage space; no space lost to bulky platforms.
  • Liquid nitrogen temperatures with no liquid nitrogen contact.
  • Vapor circulation provides better visibility in the storage area.
  • Wide lid opening for easy access to all racks.
  • Accommodates all standard rack systems.
  • Industry best temperature uniformity.

 

Custom BioGenic Systems Isothermal Freezer CBS freezers offer a wide lid opening that allows easy access to all racks and provides an extensive variety of inventory solutions
Storage of bilogical specimnes with no liquid nitrogen contact Multi-tired straw storage solution available
Split samples, chest racks and cryo bag storage Multi-tired straw storage systems for V1500 & V3000

 

Why is dry storage important? 

Safety. Storage in liquid nitrogen can make vials shrink. This may cause liquid nitrogen to seep into the vials, which on re-warming, expand and subsequently explode as nitrogen vaporizes inside the vials. Dry storage eliminates this possibility. Also, the Isothermal design provides added user safety by eliminating contact with or splashing of liquid nitrogen.

Cross Contamination. Studies have shown that viral, bacterial and fungal pathogens can survive after suspension in liquid nitrogen. Infected samples can cross contaminate other samples in the same liquid nitrogen tank. Dry storage eliminates the possibility of cross contamination.

Our 2301 controller is time tested, reliable and designed to keep your sample storage safe and secure.


New 16 Port Connector

0-5 volt outputs provide temperature & level data for connection to existing alarm/monitor system.

4-20 mA outputs provide temperature & level data for connection to existing alarm/monitor system.

Sequential and One-Fill-All-Fill input and output connection for filling systems.


New two level temperature display option

Temp. A displays temperature at the lid, approximately 11"(27.94cm).

Temp. B displays temperature inside the storage space, approximately 20"(50.80cm).

2301 controller for monitoring liquid level


Additional Features

Records 12 alarms & events such as fill start, fill stop, etc. with dated time stamp, printed or displayed.

Download cryomonitor data files to PC and convert them to .csv files for use in Microsoft Excel.

Ethernet and auxiliary RS485 for future expansion.

Dedicated 24Vdc signal output to activate a third 24Vdc valve to control the LN2 supply.

Global Remote Alarm - Dry contact that switches during any alarm condition.

Data Log - Print or display Temp. A, Temp. B and level with date and time stamp.

Műszaki specifikációk

Models / Specifications / Capacities

  V1500-AB V3000-AB V3000EH-AB V5000-AB V5000EH-AB
LN2 Capacity (liters)

30

70 89 93 140
External Width in(mm) 26 (660) 37 (939) 37 (939) 47 (1,219) 47 (1,219)
External Depth in(mm) 37 (939) 48 (1,219) 48 (1,219) 54 (1,371) 54 (1,371)
External Height in(mm) 45 (1,143) 47.5 (1,206) 58 (1,473) 52 (1,320) 58 (1,473)
Usable Interior Height in(mm) 29 (736) 29 (736) 37 (940) 29 (736) 34 (864)
Usable Interior Diameter in(mm) 21 (534) 31 (787) 31 (787) 40 (1,016) 40 (1,016)
Maximum 2ml vial capacity 9,100 22,100 25,500 40,300 46,500
Maximum 50ml bag capacity 434 1,120 1,280 1,936 2,208
Videók, ismertetők

blue down arrowForgalmazott termékeink gyártói - keressen gyártó szerint a logóra kattintva