The SpectraMax i3x Multi-Mode microplate reader measures spectral-based Absorbance, Fluorescence, and Luminescence with the added functionality of modular upgrades for Western Blot, Imaging, and Fast Kinetics with Injectors. The SpectraMax i3x reader allows you to unravel the mysteries of science by exploring cellular pathways and protein activation and expression in one system.
Protect your initial investment — purchase a system with the flexibility to add novel detection capabilities without the need for service engineers or costly system downtime. The SpectraMax i3x reader grows with you as your research areas expand.
Expanded dynamic range |
|
User-upgradeable applications |
|
One complete solution |
Investigate every aspect of a cellular pathway From imaging of cell confluence and viability under different treatment conditions to quantitation of nucleic acids and protein to western blot analysis, a wealth of new knowledge is captured using a single instrument. One versatile software package powers data acquisition and analysis, from raw data to publishable results. See more and do more cellular to protein analysis using a single detection system. |
|
Live cell imaging The SpectraMax MiniMax 300 Imaging Cytometer option allows for live cell images and analysis (top, left). The ScanLater Western Blot Detection Cartridge enables protein detection (top, right). |
Visualize cells with Imaging with the SpectraMax MiniMax 300 Imaging Cytometer mirrors the plate reading workflow on the SpectraMax i3x System. The plate is set up for reading and images are acquired according to specified parameters. Cells in each image are identified by SoftMax® Pro Software and cell-by-cell statistics are collected. Data are then analyzed and visualized in different graphical representations. |
Technical specification of the SpectraMax i3x are identical to those of the SpectraMax i3
General Specifications |
||
Dimensions (W x H x D) |
12.63 (H) x 15.38 (W) x 23.38 (D) (in) 42.23 (H) x 39.05 (W) x 59.37 (D) (cm) |
|
Weight | 68.3 lbs (31 kg) | |
Power consumption | < 200 watts | |
Power source | 100-240 VAC, 2 A, 50/60 Hz | |
Robotic-compatible | Yes | |
General Photometric Performance |
||
Plate formats | 6 to 1536 wells* | |
Light source | Spectral Fusion Illumination (Xenon flash lamp + high-powered LEDs or laser diode in detection cartridges) | |
Reading capabilities | Microplates, cuvettes (via adapter), low volume samples (via SpectraDrop, Micro-Volume Microplates) | |
Detectors | PMT and/or photodiode | |
Shaking | Linear and orbital | |
Dual Auto Injectors | Available October 1, 2015 | |
Temperature control | 4°C above ambient to 45°C | |
Temperature uniformity | ± 0.75°C | |
Temperature accuracy | ± 1°C at 37°C set point | |
Environmental control | Gas quick connect | |
Endpoint reading | all modes | |
Kinetic reading | all modes | |
Spectral scanning | Absorbance, Fluorescence, Luminescence | |
Well scanning | Over 20 by 20 in all modes | |
Wavelength selection | 1.0 nm increments | |
Standard Read Times (minutes:seconds)** |
||
96 wells | 384 wells | |
Absorbance | 0:30 | 1:40 |
Fluorescence Intensity | 0:25 | 1:25 |
Luminescence | 0:30 | 1:15 |
Absorbance Photometric Performance |
||
Wavelength range | 230-1000 nm | |
Wavelength bandwidth | 4.0 nm | |
Wavelength accuracy | ± 2.0 nm | |
Wavelength repeatability | ± 1.0 nm | |
Photometric range | 0-4.0 OD | |
Photometric resolution | 0.001 OD | |
Photometric accuracy | < ± 0.010 OD ± 1.0%, 0-2OD | |
Photometric precision | < ± 0.003 OD ± 1.0%, 0-2 OD | |
Stray light | < 0.05% @ 230 nm | |
Fluorescence Intensity Performance |
||
Wavelength range | 250-850 nm | |
Wavelength selection | 1.0 nm increments | |
Bandwidth | Adjustable: 9/15 nm (ex), 15/25 nm (em) | |
Dynamic range | > 6 logs | |
Top sensitivity (fluorescein) | ||
Optimized | ||
96 wells | 0.5 pM | |
384 wells | 1 pM | |
Bottom Sensitivity (Fluorescein) | ||
Optimized | ||
96 wells | 5 pM | |
384 wells | 5 pM | |
Luminescence Performance |
||
Wavelength range | 300-850 nm | |
Wavelength selection | Choice of simultaneous detection of all wavelengths or selection in 1.0 nm increments | |
Dynamic range | > 6 decades | |
Cross-talk | < 0.4% in white 96- and 384-well microplates | |
Sensitivity (ATP-Glow) | ||
Optimized | ||
96 wells | 3 pM | |
384 wells | 6 pM |
* 1536 detection available via detection cartridges.
** With 6 flashes in absorbance and 3 flashes in fluorescence mode, and 0.1 sec/well integration in 96-well luminescence mode and 0.04 sec/well integration in 384-well luminescence mode.
With the SpectraMax i3x Multi-Mode Detection Platform, researchers are able to use a wide range of detection cartridges, like the ScanLater Western Blot System, that provide increased plate reader functionality. The SpectraMax MiniMax 300 Imaging Cytometer option is available for cellular imaging assays and the SpectraDrop™ Micro Volume Microplates for low volume DNA, RNA and protein sample prep. Now, all of your needs are covered with a single plate reader.
Representative Applications
System Options |
|
Product | Part Number |
SpectraMax i3x Multi-Mode Microplate Reader with SoftMax Pro Software | i3x |
SpectraMax MiniMax 300 Imaging Cytometer | 5024062 |
SoftMax Pro 6.x GxP Software | by license bundle |
SpectraTest (ABS1) Absorbance Validation Plate | 0200-6117 |
SpectraTest (LM1) Luminescence Validation Plate | 0200-6186 |
SpectraTest (FL1) Fluorescence Validation Plate | 0200-5060 |
SpectraDrop Micro-Volume Starter Kit | 0200-6262 |
SpectraDrop Micro-Volume HTS Kit | 0200-6267 |
SpectraMax Detection Cartridge Options |
|
Product Name | Part Number |
AlphaScreen Detection Cartridge (384 STD) | 0200-7017POS |
AlphaScreen Detection Cartridge (384 HTS) | 0200-7018POS |
AlphaScreen Detection Cartridge (1536 HTS) | 0200-7019POS |
HTRF Detection Cartridge | 0200-7011POS |
TRF Detection Cartridges | 0200-7008POS |
Fluorescence Polarization Detection Cartridge (Fluorescein) |
0200-7009POS |
Fluorescence Polarization Detection Cartridge (Rhodamine) | 0200-7010POS |
Luminescence Detection Cartridge (Glow for 96-well plates) |
0200-7014POS |
Luminescence Detection Cartridge (Glow 96- and 384-well plates) |
0200-7015POS |
Luminescence Detection Cartridge (Glow 96-, 384-, and 1536-well plates) |
0200-7012POS |
Dual Glow Luminescence Detection Cartridge (BRET2) |
0200-7016POS |
Fluorescence Intensity Detection Cartridge (Chroma-Glo) |
0200-7013POS |
Fluorescence Intensity Detection Cartridge (Courmarin-Fluorescein) |
0200-7002POS |
Fluorescence Intensity Detection Cartridge (Fluorescein-Rhodamine) |
0200-7003POS |
Fluorescence Intensity Detection Cartridge (Cy3-Cy5) |
0200-7004POS |
Fluorescence Intensity Detection Cartridge (CFP-YFP) |
0200-7005POS |
Fluorescence Intensity Detection Cartridge (GeneBLAzer) |
0200-7006POS |
ScanLater Western Blot Detection Cartridge | 0200-7027 |
The ScanLater Western Blot Detection Cartridge is a user-installable option for the SpectraMax i3x and Paradigm® Multi-Mode Platforms. The ScanLater Western blot system simplifies the traditional western blot protocol by employing a europium-labelled secondary antibody which is then read by Time-Resolved Fluorescence (TRF). This substrate free detection method enables membrane scanning up to 30 days after the final wash step. The assay demonstrates sensitivity in the high femtogram, comparable to traditional chemiluminescence western blot methods. Leveraging this novel technology, researchers can:
Features
The SpectraMax MiniMax 300 Imaging Cytometer option, which is field-upgradeable for any SpectraMax i3x base system, provides researchers with cellular analysis capability without the need to invest in complex imaging systems.
Benefits
Features
StainFree Cell Detection Technology
The patent-pending StainFree Cell Detection technology on the SpectraMax MiniMax 300 Imaging Cytometer allows users to perform cell proliferation, cytotoxicity, and other assays without nuclear stains like DAPI or live cell dyes that are toxic to cells in the long term. Using StainFree Cell Detection Technology, users can:
The resources listed below were created using the SpectraMax i3.
Technical specifications for the SpectraMax i3x are similar to those of the SpectraMax i3. For luminescence, the LLD specification for the SpectraMax i3x is 5x lower (better) than for the SpectraMax i3.
* as of June 25, 2015. Source: Google Scholar. Search results include "SpectraMax i3" and "SpectraMax i3x".