Advantages of CESI-MS Ultra-low flow separation-ESI
High performance separation and ESI module upstream from MS | CESI technology |
---|---|
Improved ionization efficiencies result in reduced ion suppression and increased overall sensitivity. Designed for mass spectrometry applications that analyze charged and polar molecules, the CESI 8000 is the next evolution in technology. With CESI-MS the advantages of CE are delivered without dilution or disturbance to the mass spectrometer. Stable ultra-low flow ESI serves to reduce ion suppression and increases sensitivity. |
Unleash the power of CE separation for the best in mass spectrometry detection. The OptiMS cartridge assembly consists of a separation capillary terminating in the porous sprayer, a conductive liquid capillary, circulating liquid cooling, and sprayer housing. Conductive fluid is delivered automatically from a system vial that completes the CE circuit. This capillary is housed in a protective cartridge that allows easy transfer and routine use in a rugged and robust manner. With the CESI 8000 system, the cartridge simply clicks into place creating an easy-to-use plug-and-spray set up for your mass spectrometry. |
The CESI 8000 was developed in collaboration with mass spectrometry researchers covering a number of applications. They sought to expand their range of detection and increase sensitivity. In order to achieve this goal, a low flow pre-MS separation technology was integrated with novel ESI coupling technology.
Swift and simple "plug-and-spray" design increases operational efficiency
Located within a protective housing, the CESI 8000's sprayer combines an intrinsically low-flow CE separation with electrospray ionization (ESI) within a single, simple device that has no liquid junction or dead volume.
1Kelly RT, Page JS, Zhao R, Qian W, Mottaz HM, Tang K, Smith RD, Anal. Chem. 2008, 80, 143-149
2Schmidt A, Karas M, Dulks T, J. Am. Soc. Mass Spectrom. 2003, 14, 492-500
3Reprinted with permission from "High Capacity Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry: Coupling a Porous Sheathless Interface with Transient-Isotachophoresis" by Jean-Marc Busnel et al. (2010) Analytical Chemistry 82 (22), 9476-9483.
RUO-MKT-18-1951-A
A98089: CESI 8000 High Performance Separation- ESI Module
Includes CE separation module, OptiMS Sprayer cartridges, system controller pre-loaded with CESI 8000 software, portable height-adjustable lab bench designed for rapid change between LC and CESI front end.
Dimensions:
Height: 29.2 in (74.2 cm)
Door Open: 38.8 in (98.6 cm)
Width: 25 in (63.5 cm)
Depth: 28.4 in (72.1 cm)
Height Adjustable Portable Lab Bench with Memory Settings:
36 in x 30 in (91.4 cm x 76.2 cm)
Height adjustable from 27 in to 44 in (69 - 112 cm)
Weight (uncrated):
188 lbs (85.3 kg)
Electrical Requirements:
Voltage: 100 - 240 V; 50/60 Hz
Voltage Range:
1 to 30 kV programmable
at 0.1 kV increments
Current Range:
3 to 300 μA programmable
at 0.1 μA increments
Operating Environment Range:
15 - 30°C
20 - 60% relative humidity (non-condensing)
Sample Trays:
2 x 48 CESI vials / 0.3 mL microvials
Buffer Tray:
2 x 36 CESI vials
Sample Temperature Adjustment Range:
4 - 60°C
Capillary Temperature Adjustment Range:
15 - 30°C
Pressure Delivery Range:
-5 to +100 psi
Required Sample Volume:
50 μL
A98089: CESI 8000 High Performance Separation- ESI Module
Includes CE separation module, OptiMS Sprayer cartridges, system controller pre-loaded with CESI 8000 software, portable height-adjustable lab bench designed for rapid change between LC and CESI front end.