The PA 800 Plus Pharmaceutical Analysis System provides a comprehensive, automated, and quantitative solution for the characterization and analysis of proteins. Innovative system design ensures dependable operation and durability. The PA 800 Plus application menu includes SDS-gel molecular weight analysis, charge heterogeneity analysis utilizing advanced capillary isoelectric focusing technology, and carbohydrate profiling for the assessment of glycoprotein microheterogeneity. Modular design provides for the simple interchange of detectors.
The PA 800 Plus System includes:
The PA 800 Plus Pharmaceutical Analysis system, the PA 800 Plus provides an automated and quantitative solution for the analysis of protein purity and molecular weight utilizing SDS-gel capillary electrophoresis. The innovative system design ensures dependable operation and durability. Additional detectors are available for future upgrades.
A66528 PA 800 Plus Pharmaceutical Analysis System
Includes separation module with UV, photodiode array and LIF detection; system controller with PA 800 Plus software; system startup kit and reagents
A66527 PA 800S Plus Pharmaceutical Analysis System
Includes separation module with photodiode array detection; system controller with PA 800 Plus software; system startup kit and reagents
Dimensions:
Height: 29.2 in (74.2 cm)
Door Open: 38.8 in (98.6 cm)
Width: 25 in (63.5 cm)
Depth: 28.4 in (72.1 cm)
Weight (uncrated):
188 lbs (85.3 kg) (includes photodiode array detection)
Electrical Requirements:
Voltage: 100 - 240 V; 50/60 Hz
Voltage Range:
1 to 30 kV programmable at 0.1 kV increments
Current Range:
3 to 300 μA programmable at 0.1 μA increments
Pressure Delivery Range:
-5 to +100 psi
Sample Temperature Control:
4 - 60°C
Capillary Temperature Control:
15 - 60°C
Sample Trays: 2 x 96-well plates
2 x 48 universal vials 2 x 48 0.2 mL microvials
Buffer Tray:
2 x 36 universal vials
Detection Capability:
UV/Vis
200, 214, 254, 280 nm standard filter
190 - 600 nm (custom filter option)
Diode Array
190 - 600 nm (programmable)
0.5 - 32 Hz scan collection frequency (programmable)
Laser Induced Fluorescence (LIF)
300 - 700 nm excitation range
350 - 750 nm emission range
0 - 1000 RFU
Source Lasers with 3 mW Power Output:
488 nm solid-state laser (included in A66528)
A66528 PA 800 Plus Pharmaceutical Analysis System
Includes separation module with UV, photodiode array and LIF detection; system controller with PA 800 Plus software; system startup kit and reagents
A66527 PA 800S Plus Pharmaceutical Analysis System
Includes separation module with photodiode array detection; system controller with PA 800 Plus software; system startup kit and reagents