JM Modern HikaShop - шаблон joomla Видео
In
(06-1) 619-8321
BIO SCIENCE
Molecular Devices

GenePix 4300/4400 Microarray Scanner

The GenePix® 4300A and GenePix® 4400A Scanners from Molecular Devices offer maximum imaging quality with optimal resolution in highly configurable platforms. Configurations include 5μm or 2.5μm per-pixel maximum scanning resolution, choices of up to four lasers for excitation, and sixteen emission-wavelength filters. These options allow the systems to detect a wide variety of fluorophores. Coupled with GenePix® Pro Microarray Image Analysis Software and Acuity® Microarray Informatics Software, the GenePix Systems provide powerful, flexible, and easy-to-use solutions for the acquisition and analysis of data from all types of arrays, including nucleic acids, proteins, tissues, and cells.

ÁRAJÁNLATOT, INFORMÁCIÓT KÉREK!

 

High-resolution for High-density Microarrays:

  • Upgrade for the Future: While the GenePix® 4300A Microarray Scanner has a maximum resolution of 5µm per pixel; it can be upgraded to 2.5 micron per pixel resolution at any time. So you have the option to match the scanner resolution as your microarray research requirements advance.
  • Full Flexibility in Choosing Dyes: With up to four internal solid-state diode and gas lasers, the scanner is a remarkably compact bench-top unit. The laser flexibility and choice of up to 12 user-accessible emission filters allow you to select your dyes from a broad variety of fluorophores for your assay (CyTM3 and CyTM5 dyes, Fluorescein, GFP, Texas Red, Alexa Fluor® dyes, or quantum dots.
  • Trust your Microarray Signals: with outstanding positional performance and uniformity, the GenePix® 4300 and 4400 Microarray Scanners allow you to perform the most demanding application, like latest generation NimbleGen® arrays or array CGH experiments. Specified and tested for a field uniformity of +/- 2%, these scanners resolve a spatial frequency of 200 line pairs per millimeter (LPPM), and feature a contrast ratio (CTF) of least 50% at the highest resolution.
  • Less Noise in Your Data: Get unparalleled signal-to-noise (SNR) performance. GenePix® Microarray Scanners uses only the best components, like low-noise digitizer and photomultiplier tube (PMT), highest quality optical filters and sensors to reduce scattered light. Together these improvements reduce the noise to a minimum and increase the sensitivity. Unparalleled sensitivity also enables the use of lower laser power settings, which significantly reduces any perceived degradation of your dyes.
  • Less Breakable Components: Your microarray is safe in our scanner. With the newly designed six-point-slide holder, we exclusively rely on high-precision machining to eliminate fallible components as commonly used in dynamic autofocus systems.
  • Designed for High Duty-Cycle Usage: Improved high duty-cycle motors ensure maximum translation and focus motor lifetime. The new patent pending voice coil was designed to minimize vibration and optimize heat dissipation.
  • The GenePix 4400A Microarray Scanner is capable of scanning at a user-defined optical pixel resolution between 2.5 and 100 micron per pixel - allowing you to scan the highest-density microarrays on the market.

The GenePix® 4300/4400 Microarray Scanner and GenePix® Pro Microarray Analysis Software have been designed to work together as a complete, integrated platform. The seamless communication between scanner and software ensures unmatched efficiency for data acquisition and analysis, as well as for real-time scanner performance monitoring. Optional Acuity® Microarray Informatics Software completes the package, offering database storage, clustering algorithms, advanced statistics and visualizations.

 

The GenePix 4300/4400 Microarray Scanners are compatible with the following:
 
  • GenePix® SL50 Automated Slide Loader
  • GenePix® Pro 7 Acquisition and Analysis Software
  • Standard microscope slides (1" x 3", 25 x 75 mm; 0.9-1.1 mm thick)

Műszaki specifikációk

 

Maximum scan area
22 x 75 mm
Maximum resolution
4300A: 5 µm, 4400A: 2.5 µm
Scan mode and order
Sequential; fully user-configurable scan order
Excitation
Up to 4 lasers (all internal); 488 nm, 53 nm, 635nm
Laser Settings
User selectable, from 5-100% (1% increments)
Emission filters: 16 positio user-accessible filter wheel
Detector
Photomultiplier tube (PMT) automatic and manual gain adjustment settings
Focus offset
Adjustable between -50 to +200  μm (1 μm increments)
Optics
Non-confocal
Emission filters
See Configurations section below
Scanning method
Sequential
Scan time:
4 minutes per channel, 10 μm resolution, full scan area
Pixel Resolution
4300A-Adjustable from 5-100 μm, 4400A-Adjustable from 2.5-100 μm
Digital Resolution
16-bit
Image Format
Single-image or multi-image TIFF
Dynamic Range
Four orders of magnitude at SNR  > 3
Rotational Uniformity
Less than ±4% non-uniformity
Image Type
Single- or multi- image TIFF
Barcode Reading
Integrated hardware barcode reader; all common 1D and 2D barcodes

 

General Specifications

Dimensions (cm)
43 cm (16.9") x 65 cm (25.6") x 34 cm (13.4") (WxDxH)
Weight
45 kg (99 lbs)
Power Supply
85 to 264 VAC (110 to 340 VDC) universal voltage input
Line Frequency
50-60 Hz
Power
150W
Fuse
2.0 A slow. 5 x 20 mm
Dimensions (in)
16.9 (W) x 13.4 (H) x 25.6 (D)
Computer interface
USB 2.0
Applikációk

Proteomics

Although the analysis of the full proteome has not yet been achieved, rapid progress is being made with microarrays in the field of proteomics. Proteomes exhibit large and dynamic complexity; the number for distinct proteins in mammals will certainly exceed the number of genes, requiring the right technology to be in place for the analysis. The flexibility of the GenePix system, and especially the high-throughput capabilities of the GenePix® SL50 Automated Slide Loader, provides adequate tools to researchers.

  • Protein arrays 
  • Peptide arrays 
  • Antibody arrays
  • ELISA arrays
  • Reverse Phase Arrays

Genomics

Directed at the genome sequence itself, microarrays have been used to identify novel genes, binding sites of transcription factors, changes in DNA copy number, and variations from a baseline sequence, such as in emerging strains of pathogens or complex mutations in disease-causing human genes.

  • SNP genotyping arrays
  • Arrayed comparative genomic hybridization (aCGH) arrays 

Transcriptomics

The use of high-density microarrays has impacted the measurement of transcript levels to study complex diseases. With the latest development of microarray technology, it is now possible to quantify transcript levels globally and to integrate such data with information relating to disease. Microarrays based transcriptomics enables mapping a critical genomic region for a disease using affected and unaffected individuals and then pinpointing the responsible gene by identifying differentially expressed genes in the critical region.

  • Gene expression arrays
  • RNA interference (RNAi) arrays
  • MicroRNA (miRNA) arrays

Epigenomics

The gene carries the basic unit of information, but this information has an impact only once it is properly programmed by the epigenome. The DNA methylation pattern is cell type specific and correlates with chromatin structure. DNA microarrays are being utilized to identify methylation patterns, and the GenePix automation solution allows the researcher to identify these patterns faster.

  • DNA methylation arrays
  • Chromatin immunoprecipitation (ChIP) arrays

Novel Applications

The creativity and broad applicability of microarray-based research has no limits and is demonstrated by the vast variety of different microarray applications to conduct large-scale quantitative analysis. With the GenePix® Microarray Scanner System you have the most flexible solution and freedom in your research.

  • Tissue arrays
  • Quantum Dots
  • Carbohydrate Arrays
  • Chemical Compound Arrays
Tartozékok, kiszerelések

Product

Part Number

GenePix 4300A Scanner configurable with GenePix Pro, Includes 532nm green laser and 635nm red laser
GENEPIX 4300
GenePix 4400 Scanner configurable with GenePix Pro, Includes 532nm green laser and 635nm red laser
GENEPIX 4400
GenePix Pro Software v7 license 5004757
AcuityMicroarray Informatics Software ACUITY PTO

blue down arrowForgalmazott termékeink gyártói - keressen gyártó szerint a logóra kattintva