NanoDrop Lite Plus

Lite Plus 1
Lite Plus 2
Quickly and easily assess sample concentration and purity ratios with the Thermo Scientific™ NanoDrop™ Lite Plus Microvolume Spectrophotometer, the entry-level complement to the full-featured Thermo Scientific™ NanoDrop™ One/OneC and NanoDrop Eight Spectrophotometers. While offering fewer features than our premium models, this instrument delivers fast, accurate measurements in an easy-to-use, affordable package.

ÁRAJÁNLATOT, INFORMÁCIÓT KÉREK!

The NanoDrop Lite Plus Spectrophotometer is a valuable teaching tool and is ideal for quality check measurements in busy research labs as well. Measure purified DNA, RNA, and protein concentration up to 30 Abs and calculate critical A260/A280 and A260/A230 purity ratios using trusted NanoDrop technology.

 

 

The NanoDrop Lite Plus Spectrophotometer is designed for routine measurements of nucleic acid and protein samples using only 1–2 μL. Our pioneering sample-retention technology eliminates the need to dilute highly concentrated samples, making measurements easy. Simply pipette your sample directly onto the optical measurement pedestal, measure, and wipe clean with a lint-free wipe. Its compact design, with built-in controls and software, means the NanoDrop Lite Plus Spectrophotometer takes up little space on your benchtop.
 
With an intuitive user interface and modern industrial design, the NanoDrop Lite Plus Spectrophotometer is the instrument of choice for basic microvolume measurements. Even if budgets are tight, your lab can have a NanoDrop, too.
 
Confidence in your results
  • Standard measurements
    • Measures purified DNA, RNA, and protein concentration up to 30 Abs
      • Up to 1,500 ng/µL dsDNA
      • Up to 1,200 ng/µL RNA
      • Up to 45 mg/mL BS
    • Calculates critical A260/A280 and A260/A230 purity ratios
  • Fast, accurate measurements from only 1–2 µL—saves precious samples, no waste
    • Sample-retention technology uses surface tension to hold the sample in place—no cuvettes or expensive consumables are needed
  • Intuitive interface
    • Built-in touchscreen operation
    • No computer required
  • Data storage and transfer
    • Last 1,000 measurements saved locally; export data to a USB device
  • Optional printer available for freezer-compatible labels (not included)
  • Compact and portable—fits on any lab bench, ready for your next experiment
  • Affordably priced—stretch tight budgets

Műszaki specifikációk

Specifications


Instrument Type   Spectrophotometer
Minimum Sample Size 1 µl
Sample Number 1
Path Length 1 & 0.2 mm
Light Source(s) Xenon flashlamp
Detector Type Silicon photodiode
Wavelength Range 230, 260 and 280 nm
Absorbance Accuracy 3% (at 1.05 Abs at 260 nm)
Absorbance Range (10 mm equivalent) 0.04 - 30 Abs
Lower Limit of Detection 2 ng/µl (dsDNA)
0.06 mg/ml (BSA)
Maximum Concentration 1,500 ng/µl (dsDNA)
45 mg/ml (BSA)
Measurement Time < 5 seconds
Footprint 27 x 22 x 22 cm
Weight 2.7 kg
Sample Pedestal Material of Construction 303 stainless steel and quartz fiber
Operating Voltage 6 V (DC)
Operating Power Consumption 18 W
Standby Power Consumption  ≤ 3 W
Software Compatibility Local control only
Applikációk
  • The MIQE Guidelines and Assessment of Nucleic Acids Prior to qPCR and RT-qPCR
  • Measuring Viability Decline in Animal Cell Suspension Cultures Using the Thermo Scientific NanoDrop 2000 Spectrophotometer.
  • Nanoparticle Characterization Resources for the NanoDrop 2000/c Spectrophotometer
  • Quantification of Gold Nanoparticles
  • Differences in Bacterial Optical Density Measurements between Spectrophotometers
  • Activity Measurements of Pentose Phosphate Pathway Enzymes Using Kinetics
  • Quality Control during Library Construction for de novo Next-Gen Sequencing Platforms
  • Generation of a Standard Curve Based Custom Method using the NanoDrop 2000/2000c: Lowry Assay Case Study
  • Quality Control of Industrial Dye Products Using Absorbance Spectroscopy
  • Detection and Avoidance of Polysaccharides in Plant Nucleic Acid Extractions
  • Quality Control of Small Molecule Pharmaceuticals using Spectrophotometry
  • Pierce 660 nm Micro-Volume Assay Advantages
  • Use of Custom Methods Capability of NanoDrop Spectrophotometers for Toxicology Studies
  • Microvolume Quantification of Proteins by UV-Vis Absorbance or Fluorescence (Poster)
  • Microvolume Quantification of Nucleic Acids in Molecular Diagnostics (Poster)
  • Small Molecule Crystallography
  • Microgenomic Expression Profiling
  • Quantitative Real Time RT PCR
  • Nucleic Acid and Fluorescent Dye Concentration Measurement
  • HLA Typing: Template Quality Control for SSP and SSO

 

Videók, ismertetők

Brochure

 

PUBLICATIONS 


The Latest in Laboratory Apps

Lab Manager Magazine, October 2013


A Novel Process for Developing Fully Human Monoclonal Antibodies

PharmaTech, November 2012


Comparing Microvolume and Cuvette Based Measurements of Microbial Cell Cultures

Lab Manager Magazine, October 2011


Assuring Success with qPCR

Bioscience Technology, September 2011


Assuring Reliability of qPCR & RT-PCR Results

Genetic Engineering & Biotechnology News, September 2011


Empowering PCR

Bioscience Technology, September 2011


Global Incentives Seek to Buoy Innovation

Genetic Engineering & Biotechnology News, September 2011


Molecular Diagnostics: Critical Issues for Successful Translation from the Bench to the Clinic

Pharma Bio World, August 2011


PCR Gets Personal, Faster

Pharmaceutical Formation & Quality, January 2011


qPCR y RT-qPCR con garantia de exito

FARMESPANA INDUSTRIAL, January 2011


Use of Microvolume Analysis in Processing

Genetic Engineering News, March 2010


Current Protocols in Molecular Biology: "Quantitation of DNA and RNA with Absorption and Fluorescence Spectroscopy"

Presented here are the first two pages of this Protocol. Please see Wiley InterScience for full protocol details.


Current Protocols in Protein Science: "Microvolume Spectrophotometric and Fluorometric Determination of Protein Concentration"

Presented here are the first two pages of this Protocol. Please see Wiley InterScience for full protocol details.


The power to choose expands possibilities for measurement

eLab, June 2009


"Small, easy and fast": when 'less is more' in Spectrophotometry

BioTech International, March 2009


Microsample quantitation technology for molecular diagnostics

Clinical Laboratory International, October 2008


Tissue typing - just a drop in the ocean

MedLab News, October 2008


Real-Time PCR Bridges Molecular Biology and Clinical Diagnostics

Clinical Lab Products, October 2

blue down arrowForgalmazott termékeink gyártói - keressen gyártó szerint a logóra kattintva