JM Modern HikaShop - шаблон joomla Видео
In
(06-1) 619-8321
Molecular Devices

FilterMax F3 & F5 Multi-Mode Microplate Readers

See the future of your projects, sooner, with a beautifully designed F3 or F5 FilterMax Multi-Mode Microplate Reader

FilterMax F3 Multi-Mode Microplate Reader
The FilterMax F3 offers a stunning set of features at an economical price. With the F3 Reader, you get visible-wavelength absorbance, top-reading fluorescence intensity, and glow luminescence modes for programmable endpoint, kinetic, multiple-wavelength linear scan and area scan measurements in 96- to 384-well plates. Easily accessible filter slides give you wavelength selection options from 340 nm to 650 nm.

FilterMax F5 Multi-Mode Microplate Reader
The FilterMax F5 gives you an even richer set of features while maintaining an economical price-to-performance ratio. With the F5 Reader, you get UV and visible absorbance, top and bottom fluorescence intensity, glow luminescence, fluorescence polarization, and time-resolved fluorescence modes, plus temperature control and linear and orbital shaking for programmable endpoint, kinetic, multiple wavelength, linear scan, and area measurements in 6- to 1536-well plates. Filter slides on the F5 Reader give you wavelength selection options from 230 nm to 750 nm.


ÁRAJÁNLATOT, INFORMÁCIÓT KÉREK!

 

The FilterMax™ F3 and F5 Multi-Mode Microplate Readers provide value and flexibility for a variety of applications capable of performing:

  • Absorbance detection in the visible range (340 nm to 650 nm, F3) or UV and visible range (230nm to 650nm, F5)
  • Fluorescence Intensity (FI) top read
  • Fluorescence Intensity (FI) top read & bottom read (F5)
  • Luminescence (glow)
  • Fluorescence Polarization (FP) - F5
  • Time-Resolved Fluorescence (TRF) - F5
  • Scan measurement types: endpoint, kinetic, multiple wavelength, linear scan and area scan
  • Linear and Orbital shaking
  • Temperature Control

The FilterMax Series can operate as standalone instruments or can be integrated seamlessly with laboratory automation platforms, and is ideal for a broad range of applications, including drug discovery, genomics, proteomics and cell-based research. The unique patented design ensures precise performance and sensitivity across all detection modes.

 

Benefits

  • Performance driven specifications for sensitivity, dynamic range, accuracy, precision and linearity
  • Affordable multi-mode microplate reader
  • Excellent price / performance ratio

Features

  • 3 or 5 Modes of detection
  • Automatic z-height optimization (top read) (F5 only)
  • Patented LED intensity adjustment
  • Up to 384-well format
  • Filter based multi-mode

Műszaki specifikációk

General Specifications

  FilterMax F3 FilterMax F5
Light Source
High Power LEDs
High Power LEDs + Deuterium Lamp
Detectors
Silicon Photodiode + PMT
Filters
1 EX + 1 EM Filter Slides (6 filter capacity)
 
2 EX + 1 EM Filter Slides (6 filter capacity)
Plate Formats
96-384 well
 
6-1536 well
Measurement Methods
Endpoint, Kinetic, Linear Scan, Area Scan
Shaking
Linear + Orbital (3 speeds)
Temperature Control
n/a
Ambient +4°C to 45°C
Power/Voltage
100-240VAC; 50/60Hz
Dimensions
39cm W x 24cm H x 58cm L
Weight
25 kg
Fluorescence Intensity (FI) - Top Read
Wavelength Range
 
340-650nm
 
230-750nm
Detection Limit--96 well plate
 
3 fmol/200µl fluorescein
 
0.5 fmol/200µl fluorescein
Detection Limit--384 well plate
 
3 fmol/100µl fluorescein
 
0.4 fmol/100µl fluorescein
Linear Dynamic Range
 
6 decades
Read Time (Fly mode)
 
18sec/96well; 37sec/384well
Fluorescence Intensity (FI) - Bottom Read
Wavelength Range
 
n/a
 
300-650nm
Detection Limit--96 well plate
 
n/a
 
25 fmol/200µl fluorescein
Detection Limit--384 well plate
 
n/a
 
15 fmol/100µl fluorescein
Time-Resolved Fluorescence (TRF)
Wavelength Range
 
n/a
 
340-750nm
Detection Limit--96 well plate
 
n/a
 
30 amol/200µl Europium
Detection Limit--384 well plate
 
n/a
 
15 amol/100µl Europium
Linear Dynamic Range
 
n/a
 
5 decades
Read Time (1sec integration)
 
n/a
 
180sec/96well; 690sec/384well
Fluorescence Polarization (FP)
Wavelength Range
 
n/a
 
300-750nm
Detection Limit--96 well plate
 
n/a
 
3 mP at 10nM Fluorescein
Detection Limit--384 well plate
 
n/a
 
4 mP at 10nM Fluorescein
Read Time (Fly mode)
 
n/a
 
38sec/96well; 79sec/384well
Luminescence (LUM) - Glow
Wavelength Range
 
400-650nm
 
400-750nm
Detection Limit--96 well plate
 
2 fmol ATP
Linear Dynamic Range
 
6 decades
Read Time (Fly mode)
 
18sec/96well; 37sec/384well
Absorbance (Abs)
Wavelength Range
 
340-650nm
 
230-650nm
Indication Range
 
0-3.5 OD
Accuracy
 
<+1%+10mOD at 2 OD
Reproducibility
 
<+0.5% and +0.005 OD at 2 OD
Read Time
 
18sec/96well; 37sec/384well
Operating System
Item
Minimum
Recommended
Processor Single-core, 2 GHz or faster Quad core or faster
Operating System
Window 7, 32-bit or 64-bit (x86 or x64) and .NET Framework 4.0 (.NET Framework is installed automatically by the SoftMax Pro Software installer if necessary)
Windows 7, 32-bit or 64-bit (x86 or x64), or Windows 8, 32-bit or 64-bit (x86 or x64)
Data Connection RS-232 serial port or USB 2.0 port (depending on the instrument) USB 2.0 ports; For those that require an RS-232 serial port, you can use a USB 2.0 port with a Keyspan, USB-to-serial adapter. Keyspan USB-to-serial adapters have been field tested and approved by Molecular Devices.
Memory 2 GB RAM 4GB RAM; If running on a virtual machine, Molecular Devices recommends a minimum of 6 GB RAM. For automation, Molecular Devices recommends a minimum of 8 GB RAM.
Hard Disk 500 MB of available space 1 GB of available space or more
Graphics Display Graphics display adapter 1024 x 768 or higher resolution display 32-bit graphics display with 265 MB video RAM;
1280 x 1024 or higher resolution display
Software Installation and Activation CD/DVD drive; Internet connection or external USB drive CD/DVD drive; Internet connection
Applikációk

From basic research to drug discovery, the FilterMax series cover a range of applications at an affordable price without sacrificing performance of your multi-mode microplate reader.

Representative Applications

  • Apoptosis
  • Cell proliferation, viability, cytotoxicity
  • ELISA
  • Endotoxin tests, agglutination assays
  • Enzyme activity and kinetic assays
  • Genotyping
  • GPCRs
  • Molecular interactions
  • Nucleic acid and protein quantitation
  • Proliferation assays
  • Reporter gene assays with fluorescent proteins (GFP)
Tartozékok, kiszerelések

 

Product

Product Number

FilterMax F3 Microplate Reader F3
FilterMax F5 Microplate Reader F5
FilterMax FLUORESCENCE EXCITATION FILTER 360NM BW 35NM
6590-0042
FilterMax FLUORESCENCE EXCITATION FILTER 485NM BW 20NM
6590-0043
FilterMax FLUORESCENCE EXCITATION FILTER 535NM BW 25NM
6590-0044
FilterMax FLUORESCENCE EXCITATION FILTER 430NM BW 35NM
6590-0045
FilterMax FLUORESCENCE EXCITATION FILTER 590NM BW 20NM
6590-0046
FilterMax FLUORESCENCE EXCITATION FILTER 320NM BW 25NM
6590-0047
FilterMax FLUORESCENCE EXCITATION FILTER 405 NM BW 30NM
6590-0048
FilterMax FLUORESCENCE EXCITATION FILTER 465NM BW 35NM
6590-0049
FilterMax FLUORESCENCE EXCITATION FILTER 500NM BW 25NM
6590-0050
FilterMax FLUORESCENCE EXCITATION FILTER 518NM BW 26NM
6590-0051
FilterMax FLUORESCENCE EXCITATION FILTER 525 NM BW 45NM
6590-0052
FilterMax FLUORESCENCE EXCITATION FILTER 540NM BW 25NM
6590-0053
FilterMax FLUORESCENCE EXCITATION FILTER 550NM BW 10 NM
6590-0054
FilterMax FLUORESCENCE EXCITATION FILTER 585NM BW 10NM                                               
6590-0055
Fluorescence (FI) Emission Filters
Description
 
FilterMax FLUORESCENCE EMISSION FILTER 465NM BW 35NM
6590-0056
FilterMax FLUORESCENCE EMISSION FILTER 535NM BW 25NM
6590-0057
FilterMax FLUORESCENCE EMISSION FILTER 595NM BW 35NM
6590-0058
FilterMax FLUORESCENCE EMISSION FILTER 625NM BW 35NM
6590-0059
FilterMax FLUORESCENCE EMISSION FILTER 430NM BW 35NM
6590-0060
FilterMax FLUORESCENCE EMISSION FILTER 650NM BW 40NM
6590-0061
FilterMax FLUORESCENCE EMISSION FILTER 485NM BW 20NM
6590-0062
FilterMax FLUORESCENCE EMISSION FILTER 500 NM BW 25NM
6590-0063
FilterMax FLUORESCENCE EMISSION FILTER 550NM BW 10NM
6590-0064
FilterMax FLUORESCENCE EMISSION FILTER 574 NM BW 25NM
6590-0065
FilterMax FLUORESCENCE EMISSION FILTER 585NM BW 10NM
6590-0066
FilterMax FLUORESCENCE EMISSION FILTER 635NM BW 35NM
6590-0067
FilterMax FLUORESCENCE EMISSION FILTER 660NM BW 32NM
6590-0068
FilterMax FLUORESCENCE EMISSION FILTER 668NM BW 12NM
6590-0069
FilterMax FLUORESCENCE EMISSION FILTER 670NM BW 40NM
6590-0070
 
Fluorescence Polarization (FP) Filters
Product Name
Product Number
FilterMax FLUORESCENCE POLARIZATION (FP) Excitation Filter Visible                               6590-0071
FilterMax FLUORESCENCE POLARIZATION (FP) Emission Filter Visible (QTY 2)
6590-0072
 Time-Resolved Fluorescence (TRF) Filters
Product Name
Product Number
FilterMax TIME RESOLVED FLUORESCENCE (TRF) Excitation Filter 370NM BW80 NM                         
6590-0073
 Absorbance Filters
Product Name
Product Number
FilterMax ABSORBANCE FILETER 280NM BW 5,5NM                                                                     6590-002
FilterMax ABSORBANCE FILTER 260NM BW 5,5NM 6590-001
FilterMax ABSORBANCE FILTER 320NM BW 5,5NM
6590-0003
FilterMax ABSORBANCE FILTER 420NM BW 8NM
6590-0004
FilterMax ABSORBANCE FILTER 450NM BW 8NM
6590-0005
FilterMax ABSORBANCE FILTER 465NM BW 8NM
6590-0006
FilterMax ABSORBANCE FILTER 470NM BW 8NM
6590-0007
FilterMax ABSORBANCE FILTER 480NM BW 8NM
6590-0008
FilterMax ABSORBANCE FILTER 490NM BW 8NM
6590-0009
FilterMax ABSORBANCE FILTER 492NM BW 8NM
6590-0010
FilterMax ABSORBANCE FILTER 510NM BW 8NM
6590-0011
 FilterMax ABSORBANCE FILTER 515NM BW 8NM
6590-0012
 FilterMax ABSORBANCE FILTER 520NM BW 8NM
6590-0013
FilterMax ABSORBANCE FILTER 532NM BW 8NM
  6590-0014
FilterMax ABSORBANCE FILTER 540NM BW 8NM
6590-0015
FilterMax ABSORBANCE FILTER 548NM BW 8NM
6590-0016
 FilterMax ABSORBANCE FILTER 550NM BW 8NM
6590-0017
FilterMax ABSORBANCE FILTER 560NM BW 8NM
6590-0018
 FilterMax ABSORBANCE FILTER 562NM BW 8NM
6590-0019
FilterMax ABSORBANCE FILTER 570NM BW 8NM
6590-0020
 FilterMax ABSORBANCE FILTER 575NM BW 8NM
 6590-0021
FilterMax ABSORBANCE FILTER 580NM BW 8NM
6590-0022
FilterMax ABSORBANCE FILTER 590NM BW 8NM
6590-0023
 FilterMax ABSORBANCE FILTER 595NM BW 8NM
6590-0024
 FilterMax ABSORBANCE FILTER 600NM BW 8NM
6590-0025
FilterMax ABSORBANCE FILTER 610NM BW 8NM
6590-0026
FilterMax ABSORBANCE FILTER 620NM BW 8NM
6590-0027
FilterMax ABSORBANCE FILTER 630NM BW 8NM
6590-0028
 FilterMax ABSORBANCE FILTER 640NM BW 8NM
6590-0029
 FilterMax ABSORBANCE FILTER 645NM BW 8NM
6590-0030
FilterMax ABSORBANCE FILTER 650NM BW 8NM
6590-0031
FilterMax ABSORBANCE FILTER 340NM BW 10NM
 6590-0032
 FilterMax ABSORBANCE FILTER 350NM BW 10NM
 6590-0033
FilterMax ABSORBANCE FILTER 360NM BW 10NM
6590-0034
 FilterMax ABSORBANCE FILTER 370NM BW 10NM
6590-0035
FilterMax ABSORBANCE FILTER 380NM BW 10NM
6590-0036
FilterMax ABSORBANCE FILTER 405NM BW 10NM
6590-0037
 FilterMax ABSORBANCE FILTER 414NM BW 10NM
6590-0038
 FilterMax ABSORBANCE FILTER 260NM BW 12NM
6590-0039
FilterMax ABSORBANCE FILTER 280NM BW 12NM
6590-0040
FilterMax ABSORBANCE FILTER 320NM BW 12NM
 6590-0041
Videók, ismertetők

FilterMax F3/F5 brochure

 

Number of Citations*: 126

.

Identification of phenolics in litchi and evaluation of anticancer cell proliferation activity and intracellular antioxidant activity

L Wen, L You, X Yang, J Yang, F Chen, Y Jiang… - Free Radical Biology …, 2015 - Elsevier
... Quercetin was used as positive control. The fluorescence generation was measured every 5
min for 35 cycles using a multimode microplate reader (Filter Max F5, Molecular Devices, USA)
with an excitation wavelength of 485 nm and an emission wavelength of 538 nm. ...
Related articles All 3 versions Import into BibTeX Save More

The NADPH oxidase inhibitor DPI can abolish hypoxia-induced apoptosis of human kidney proximal tubular epithelial cells through Bcl2 up-regulation via ERK …

H Song, IY Han, Y Kim, YH Kim, IW Choi, SK Seo… - Life sciences, 2015 - Elsevier
... The cells were then incubated with 10 μL of WST-1 reagent at 37 °C for 4 h. The absorbance
of the cell cultures was measured at a wavelength of 450 nm using a Molecular Devices Filter
MAX F5 microplate reader (Molecular Devices, Sunnyvale, CA, USA). ...
Cited by 2 Related articles All 4 versions Import into BibTeX Save More
 

[HTML] Rapid and Liquid-Based Selection of Genetic Switches Using Nucleoside Kinase Fused with Aminoglycoside Phosphotransferase

M Tominaga, K Ike, S Kawai-Noma, K Saito, D Umeno - PloS one, 2015 - dx.plos.org
... The fluorescence intensity (488 nm excitation, 507 nm emission [16]) of each sample was
measured using a fluorescence microtiter-plate reader (FilterMax F5, Molecular Devices,
Sunnyvale, CA, USA) with excitation at 485 nm and emission at 535 nm. ...
Related articles All 7 versions Import into BibTeX Save More

Phenolic contents and cellular antioxidant activity of Chinese hawthorn “Crataegus pinnatifida”

L Wen, X Guo, RH Liu, L You,

blue down arrowForgalmazott termékeink gyártói - keressen gyártó szerint a logóra kattintva